(761 products available)
The Siemens current transformer is a vital component in measuring and protecting electrical devices. It helps to ensure that electrical systems work reliably and safely. Current transformers, or CTs, come in different types based on what they do and how they are built. These types are made for specific jobs.
This powerful tool can reach ratios of 2000:1. This means that when a large current goes through the primary side, only a tiny fraction of it flows through the secondary side.
Rogowski coil CTs
A Rogowski coil has a flexible, insulated wire that wraps around the wire carrying the main current. This CT measures alternating current without needing direct contact with the wire. It is lighter and simpler than other methods, giving it an edge when measuring currents in hard-to-reach places. The coil can bend around the wire, making it useful for moveable applications like monitoring current changes in machinery or power lines.
Split-core CTs
A split-core CT has two parts that fit together around a wire and snap shut. It does not need to be permanently fixed because it can open and close around the main wire. This current transformer model allows for easy installation without disrupting the system. It is frequently used to observe systems without having to fully shut them down or take off the core.
Wound primary CTs
This type of power transformer is different because the primary part, where the main current flows, is actually built into the transformer. It gives the needed ratio of high current to a safer, much lower current. It is also used when the reduction ratio needs to be precise. As a result, it is often used in low-resistance applications where high accuracy is required.
Instrumental CTs
Instrumental CTs are made to supply low secondary currents to electrical instruments used in measurement systems. These include meters and relays, which monitor electrical variables. Designed for very precise secondary current outputs, these CTs allow measuring voltage, current, and power in systems safely.
Protection CTs
These CTs are designed to handle much larger currents while maintaining lower secondary currents to feed protection devices like relays. The primary purpose of protection CTs is to provide inputs to overcurrent and fault protection relays.
Choosing the right current transformer involves considering several important factors to ensure it meets the specific application requirements.
Pick the right type of CT
The CT type will depend on the alternating current current and the electrical system setup. Apply Rogowski coil and Split-core types for easy installation and non-invasive measurement. Use wound primary CTs when the current must pass through a coil to measure. Select instrumental CTs if the goal is to measure current, voltage, and power safely.
Determine the correct ratio
Select a CT with the right ratio for the target current load. The ratio refers to the relationship between the primary current and the secondary current. Ensure the CT can lower the high primary current to a safe secondary current for use with instruments and equipment.
Check the accuracy class
It is important to ensure measurement results are correct. Higher accuracy classes allow better meter performance. Choose a CT based on whether it will be used for general loads or critical applications requiring higher precision.
Evaluate the insulation rating
Insulation protects against dangerous voltages. This ensures the safely of not only the device but also of the surrounding equipment and operators. Ensure the insulation class matches system voltage levels. This prevents failure or danger at high voltages.
Consider the physical size and mounting options
The physical shape and mounting must fit in the available space while allowing easy connection to the main power lines. Determine whether a CT will be fixed permanently or if it needs the flexibility to snap on and off.
Current transformers have important technical features and must be regularly repaired and maintained to work properly. This means that they can increase safety and efficiency in electrical systems.
Technical specifications
The main features of current transformers include ratio, accuracy, power rating, and more. The ratio compares the primary current flowing through the transformer to the secondary current used by devices. Common ratios are 100, 200, up to 2000 amperes.
Class 0.2, 0.5, or 1 precision levels enable meter accuracy.
Texas Instruments power ratings measure how much power the CT can handle without harm, usually in volt-amperes.
Insulation levels identify voltage tolerances for safety. Make sure that the CT selected has these features and parameters within the desired ranges for the specific function.
Routine check-ups
Frequent assessment finds problems early. Visually check transformers for dirt and damage. Test circuits and connections to make sure they are working right. Look for strange sounds or warming up. Assess oil in insulated ones to spot issues.
Calibration
Calibration makes sure the CT gives the right results. Set ratios and other factors by comparing the transformer's output to the standard.
Replacement of damaged parts
Change worn parts such as insulation that is old or frayed, wires that have been worn down, or coils that are damaged. Ensure the system stays safe. Spotting and fixing worn components helps the system stay safe and work well consistently. Failure to change things like damaged coils or frayed wires can reduce efficiency and spark trouble, like overheating or even breaking the entire system down.
Use of quality parts
This applies to both Siemens current transformers and their parts. Make sure all parts are durable.
Storage in clean environment
Store transformers in dust-free, low-humidity places. Protect them from harsh weather, so they last longer.
Power plants
Siemens CTs in power plants help to monitor very high currents safely. They transform dangerous levels of primary current to lower secondary currents for instrumentation. This allows plant operators to track power flow and function smoothly. CTs also protect by sending alarms at overcurrents to ensure safeguarding.
Industrial settings
Current transformers are heavily employed at manufacturing facilities to monitor motor currents and load amounts. They help in controlling big machinery by lowering currents that are too high for gauges. Their role in overload protection keeps equipment from damage. This increases safety levels.
Commercial buildings
Commercial space electrical systems use current transformers for meter inputs. They permit utility monitoring while protecting metering devices from main current levels. This enables building managers to control power usage for cut cost and boost system efficiency.
Utility grids
CTs are key in substations along power lines. They measure system currents to calculate voltage and power flow through grids. This keeps utility grids stable and reliable. CTs give protection by presenting currents to relays that secure lines and equipment from faults.
Renewable energy systems
CTs are located in solar and wind installations. They measure currents created by these energy sources. This helps operators know how much power is produced. CTs also provide protection by keeping track of any current problems. This keeps the system safe.
Automated control systems
CTs are used by industrial control systems. They enable automatic monitoring of motor and machinery currents. This data helps controllers optimize performance. Detect overloads and save energy. CTs further provide safety by ensuring that equipment operates within proper limits.
A1: Current transformers lower large electrical currents to safer levels for metering devices.
A2: It creates a smaller secondary current proportional to the primary current for measurement purposes.
A3: Open-core, split-core, and Rogowski coil CTs are the most popular.
A4: Ratio, accuracy, and insulation class must be suitable for the application requirements.