All categories
Featured selections
Trade Assurance
Buyer Central
Help Center
Get the app
Become a supplier

About microscope olympus parts

Types of Microscope Olympus Parts

Microscope Olympus parts are many, and they can help remove the faulty parts of an Olympus microscope. It can help fix the device and even provide some upgrades to make it better and perform better. Below are some parts and accessories for an Olympus microscope.

Objective lenses

Like every other modern microscope, objective lenses are designed to help with magnification. Olympus has different objective lenses for its microscopes to improve different aspects of the view, such as resolving power, contrast, and working distance. The microscope lenses are made of high-quality glass and crafted with precision to give the best view possible. Olympus also has a diascopic lens available to watch the specimen through transmitted light. Olympus also has anachronistic lenses which enable the user to view 3D images of the specimen for an image-stacking effect.

Condenser

Olympus condenser focuses light onto the specimen to give clear illumination. Olympus has different condenser lenses optimized for mica-scopy and apochromatic objectives to improve the quality and clarity of the view. They also have diaphragm and filter holders to enhance magnification and illumination.

Stage

This part of Olympus microscope is used to hold the slides in place for viewing. Most stages, such as XY and fixed ones, have controls that move the stage, allowing the user to move the slide in different directions to see all the parts of the slide. Olympus also offers upgraded stages, such as automated electronic ones that provide greater stage precision and easier interactions with the microscope.

Alice and Iris diaphragms

Alice and Iris diaphragms are used to control the aperture of condenser elements. Users can smoothly adjust light passage and provide optimal illumination for objective lenses and specimens. Both adaptations are compatible with Olympus and Nikon microscopes. The Alice and Iris diaphragms improve view clarity by reducing light aberrations.

Eyepiece

Olympus Eyepieces provides ocular and stereo models suitable for different viewing types. Ocular views are optimized for monocular or binocular setups and have reticles for measurements. Stereo eyepieces give depth to the pair for 3D viewing. All Olympia eyepieces provide comfort while viewing objects for long hours with minimal distortion.

Specifications and Uses of Microscope Olympus Parts

Microscope Olympus parts have different specifications and uses. Below is the rundown.

Objective lenses specifications and uses

  • Magnification power: These lenses have different types of magnification power, from low to high. Olympus objective lenses use Infinity-Corrected Optical System for sharp, well-corrected images at all magnifications.
  • Lens material: They use premium optical glass. The glass is carefully treated with anti-reflective coatings to minimize light loss and allow maximum light passage. This gives a bright, clear view of specimens.
  • Compatibility: The lenses are compatible with Olympus microscopes and other branded models with infinity-correct.
  • Use: They are mainly used in medical and biological research to view cells and tissues. They are also used in industrial applications for quality control and material inspections.

Condenser specifications and uses

  • Lens material: Like other Olympus parts, the Olympus condenser uses high-quality glass lenses.
  • Illumination: The condenser has adjustable apertures and diaphanism that enhance light concentration and illumination.
  • Compatibility: The condenser is designed for Olympus microscopes but can fit other models.
  • Use: The condensing system is used in biology and material science. It is used in mineral specimens and biological tissues.

Stage specifications and uses

  • Material: The stage uses durable aluminum and provides a smooth, stable surface with excellent rigidity and strength.
  • Controls: The stage features coaxial mechanical controls with vernier scales for precise movements. It also features sliding welcome plates to position the specimen securely.
  • Size: The stage is usually 130 × 130 mm. It is compatible with Olympus microscopes that require a standard-size stage.
  • Use: The stage is mainly used in educational and professional labs. Users need detailed views of slides for their work.

Alice and Iris diaphragms specifications and uses

  • Material: The diaphragms use stainless steel for longevity and easy adjustability of aperture sizes.
  • Adjustment: It has a knob that users can easily adjust, allowing smooth light passage control.
  • Size: It fits standard condenser units with a diameter of 51 mm.
  • Use: Both diaphragms are used with Olympus and Nikon microscopes and control light passage to enhance illumination.

Eyepiece specifications and uses

  • Magnification: The eyepieces provide magnification of 10X and 20X. It also supports 3D viewing when used with stereo models.
  • Reticle: Some models are equipped with a built-in reticle for measurements.
  • Field of view: They have a wide field of view to provide clear and detailed views.
  • Use: The eyepiece is mainly used in labs and industries. They are also ideal for geologists and fieldwork.

How to DIY and How to Install or Replace Microscope Olympus Parts

Here is a detailed DIY guide and installation for various Olympus microscope parts.

DIY: Microscope Olympus Parts

  • Objective lenses: First, Olympus objective lenses are complex parts. So, it is not advisable to try fixing them without experience.
  • Condenser: Like the objective lens, replacing the internal parts of the condenser is very complex. One needs experience working with microscopes to complete the task.
  • Stage: To remove the microscope stage, the user should unscrew the screws holding the stage and take it out. The new stage is then positioned correctly. The stage is then rotated, and the screws are reinserted to fix the position.
  • Diaphragm: The Alice and Iris diaphragms are fixed on the condenser, so the instructions for replacing the stage apply here too.
  • Eyepieces: This is the simplest fix. The eyepiece tube has a locking ring. The old eyepiece should be taken out, and the new one is put in place. The locking ring is then screwed back to secure the eyepiece.

Installing and replacing

  • Objective lenses: When replacing objective lenses, users should ensure they use the right magnification power. Lenses should be turned and inserted into the objectives and tightened to secure them.
  • Condenser: To replace the condenser, the user should first disconnect the old one and then fix the new one onto the stage.
  • Stage: To install the new stage, position it correctly over the four mounting holes and then secure the screws.
  • Diaphragm: For diaphragm replacement, first detach the old diaphragm from the condenser and then fix the new one.
  • Eyepieces: The Old eyepiece should be taken out, and the new one should be fixed with the eyepiece tube.

Tips when Installing or Replacing Microscope Olympus Parts

Below are some important tips when replacing or installing Olympus microscope parts.

  • The user should always consult the user manual for their specific microscope model. It does provide important OEM information on part compatibility and installation procedures.
  • Whole steps should be performed carefully, so using gentle force is important. It helps prevent damage to sensitive components and internal parts.
  • Non-magnetic tools should be used in the process because magnetic tools can damage the lenses and other vital parts.
  • Users should fix all the screws after displacing any part of the Olympus microscope.

Q&A

Q1. Is it safe to administer DIY on Olympus microscope repair?

A1. As highlighted above, replacing and fixing parts of Objective lenses, glasses, and condensers requires experience. DIY tips are quite clear on how to replace or fix parts, but it is advisable to hire a professional for the hard tasks and something as delicate as a microscope.

Q2. When to replace parts?

A2. One should replace microscope parts when they become damaged, worn out, or less functional. The user should start by conducting an inspection and replacing the internal components he considers unfit.

Q3. Are microscopes of the eyepiece interchangeable?

A3. Unfortunately, due to the difference in magnification power, objective lenses, and design types, Olympus eyepieces are interni-capped only with infinity-corrected microscopes.

Q4. How does one maintain microscope parts?

A4. Regular cleaning with soft, lint-free cloths and appropriate lens paper is one of the best ways. It is also important to avoid using harsh chemicals.

Q5. How to store Olympus parts?

A5. Microscopes or microscopic parts should be kept in dry, dust-free environments. They should be covered with protection.