Types of 11kv siemens vacuum circuit breaker

An 11kV Siemens vacuum circuit breaker is designed to interrupt 11,000 voltage levels. Siemens's first breakthrough with the VCB technology came in the 14th decade. What followed was a consistent evolution of the circuit breaker With each new model boasting better technical parameters and reliability.

VABs, VRB, and VEB are some of the most popular vacuum circuit breakers that business owners can supply to their clients. Following are the details of the types:

Double Breaking Vacuum Circuit Breaker

As the name implies, double-breaking VCBs feature two breaking chambers. The chambers allow the equipment to clear a fault condition better than a single-breaking circuit breaker. While the operation principle remains consistent with the single-breaking VCB, the inclusion of two contacts into the chamber doubles the breaking power.The result is improved fault-current interrupt capability.

Double-breaking vacuum circuit breaker working principle is similar to that of a single breaker. Nevertheless, it features enhanced efficiency. Other features include:

  • Increased Reliability

    One of the most notable benefits of DBCV is its increased reliability on the grid. Thanks to the two-breaking chambers, the VCB can handle large current with minimal risk of damage. This makes them ideal for high-risk environments.

  • Reduced Downtime

    Refer to the above point. One reason may be that the circuit breaker can handle large currents.

    Furthermore, when the breaker is able to interrupt fault currents seamlessly, it eliminates the possibility of system failure. When there is minimal risk of failure on the breaker, operations on the electrical grid can also continue minimally.

Single Breaking Vacuum Circuit Breaker

The single-breaking vacuum circuit breaker comprises a single breaking chamber and one contact. The chamber serves to enclose the electrical contacts. On the other hand, the chamber uses the vacuum to quench the arc when the contacts open. The Siemens vacuum circuit breaker parts are obtainable in different types. Each variety is manufactured for VCBs to function in distinct voltage ranges. For instance, the parts meant for 11 kV VCB are destined to interleave smoothly with the VCB operating and interrupting currents safely at 11,000 volts.

Multi Chamber Vacuum Circuit Breaker

The multi-chamber VCB features multiple breaking chambers and each chamber is divided by a baffle plate. The plate serves to allow the arc transfer from one chamber to another. The circuit breaker also functions through a single mechanism. However, the mechanism requires an additional time to trip the contacts in each chamber simultaneously.

The VCB includes several features. These are some of its features:

  • High Breaking Capacity

    This vacuum isolation circuit breaker is ideal for higher short circuit current. Its ability to easily absorb large current means enhanced safety. Furthermore, with enhanced safety comes reliability in areas exposed to heavy incident electrical.

  • Effective Arc Quenching

    Each chamber is fitted with its own set of contacts. So when the arc is established in one chamber, the contacts begin to separate. This will eventually cause the arc to transfer to the next chamber. There, the vacuum will quench the arc. Multiplying the chambers means increasing the distance between contacts to enhance the arc-extinguishing time. This makes the breaker much more efficient.

Industrial Applications of 11kV siemens vacuum circuit breaker

Substation Operating

A modern-day electrical substation runs on various electrical and electronic equipment such as a Siemens 11KV vacuum breaker. Vacuum circuit breaker operating principle states that the breaker helps regulate electrical power in the station. It does this by switching between various operational states and protecting faults. Since vacuum circuit breakers are efficient, they are most commonly used in indoor substations.

Power Distribution

In power distribution, electricity from power plants is transmitted through a network of cables. During this complicated process, 11kV Siemens vacuum circuit breakers offer protection and control over electrical power. They ensure power reliability by preventing outages and electrical surges and automatically shutting down faulty parts of the system.

Electromechanical Equipment

These tools have electromagnetic fields under which they operate. Some common electro-mechanical tools include relays, inductors, and motors. In these tools, vacuum circuit breakers play an indispensable role. They protect equipment from electrical surges, control electrical currents, and ensure the tools stay operational.

Factory Machines

Many factories rely on these machines to keep production at an all-time high. Some of the most common factory machines include conveyors, compressors, and pumps. In these, Siemens VCB 11KV price will protect the machine from power surges, ensure the factories keep working, and increase safety.

Industrial Plants

These are facilities where raw industrial materials undergo a conversion process. Some common examples are chemical plants and oil refineries. In these large facilitates, vacuum circuit breakers will provide electrical control and protection. They will ensure the systems operate optimally.

Transportation Systems

Transportation systems are transport mediums such as railway networks and electric vehicle charging systems. Siemens vacuum circuit breakers in these systems control and distribute electrical power.

Renewable Energy Systems

With the advancement of technology came newer energy sources like wind and solar power. These systems require circuit breakers to help manage electricity generated. Hence, the 11kV Siemens vacuum circuit breaker manual can be helpful in this situation. The breaker will keep the systems safe while ensuring operating efficiency.

Commercial Buildings

Large commercial buildings have various modern electrical systems. Offices, hotels, and malls often use an 11kV vacuum circuit breaker to protect electrical systems. The circuit breaker operates steadily to ensure an uninterrupted power supply.

Product Specifications & Features of 11kV siemens vacuum circuit breaker

Key Features

  • Arc Quenching

    This is perhaps the main feature that makes VCB ideal for high-voltage applications. When the electrical contacts separate in a vacuum chamber, an electric arc is formed. This arc is characterized by a short period of intense light. Under normal conditions, the arc would create a significant threat to the circuit.

    However, thanks to the vacuum chamber, the arc will not be able to sustain itself. This is because the chamber is at a low pressure. Remember, when an arc is generated, a small amount of gas will be released. The gas is unable to go back into the chamber due to the pressure offset. For this reason, the arc is unable to sustain itself.

    After creating the arc, the contacts will continue to separate until the voltage will drop to a point where the arc can no longer sustain itself. This is how the circuit is interrupted by a vacuum circuit breaker.

  • High Insulation

    Insulating a vacuum circuit breaker ensures they continuously protect the transient electrical surge. Other than electrical surges, they also protect short circuit currents and switching operations. All these contribute to a VCB’s versatility and operational reliability in different environments.

  • Mechanism

    Electrical energy generated by the VCB mechanism is transformed into a valve. This valve is used to execute the circuit. Note that the mechanism must be carefully designed with durable materials such as metal alloys. While there are many ways to design the mechanism, the best way is to do it as simply as possible. Complex mechanisms are prone to malfunction and may require constant maintenance, which can be costly.

  • Safety

    VCBs come with so many safety features to ensure seamless circuit failure even in the worst possible electrical conditions. Some of these safety features include surge arresters and interlocks.

How to Install

  • Location Selection

    Remember that an indoor circuit breaker requires a clean and controlled environment. On the flip side, an outdoor vacuum circuit breaker should be positioned in an area that is shielded from adverse weather conditions.

  • Foundation Preparation

    Ensure that a strong and level foundation is prepared for the breaker installation. In the case of a Gas Insulated Switchgear VCB, a strong metallic enclosure will be required. For an outdoor VCB, there is a need to have a protective foundation or structure.

  • Electrical Connection

    Beginning from the load side, the first step of installing a VCB is to make electrical connections. This means connecting the breaker into the existing electrical system. Ensure the connections are done properly.

Maintenance and Repair

  • Regular Inspection

    Regular inspection involves checking for general wear and tear, dust accumulation, etc. The inspections should also include electrical connections to ascertain none have become loose.

  • Vacuum Level Monitoring

    This means monitoring the vacuum level in the breaker chambers. Low levels cause the arc to quench poorly. Hence, there should a professional repair the level.

  • Seal Inspection

    Vacuum circuit breakers have seals that inevitably degrade with time and usage. Regular inspector ensures that the seals are in good condition to prevent the vacuum from leaking.

  • Contact Wear Measurement

    Each breaker has built-in electrical contacts. With regular use, these contacts wear down. Proper maintenance requires measurement and assessment of the contacts and their replacement once worn down.

Quality & Safety of 11kV siemens vacuum circuit breaker

The quality and safety of a vacuum circuit breaker are vital to its performance. Remember that an 11KV VCB price is responsible for interrupting high electrical currents. So its quality, safety, and reliability are crucial when protecting people and property. Here are some these quality and safety considerations:

The Sealing

The seals are typically made of high-quality materials such as metals and rubber. They are responsible for maintaining the vacuum in the chambers. If the seal degrades or its integrity is compromised, the vacuum will be lost. As stated earlier, the loss of vacuum can lead to dangerously high levels of arcing.

For this reason, using a VCB with durable and resilient seals is recommended. At the same time, regularly check the plugs for wear and tear. Replace them if need be. The most common one can prone to deterioration is the O-ring seal. That’s why it is recommended to use nitrile or silicone O-rings that can resist heat.

Testing of Insulation

Prepare the foundation that supports the VCB. Instead, focus on its insulation properties. The most common material used to insulate VCB is porcelain. Porcelain makes great insulators because it’s highly resistant to electrification. However, the material is susceptible to cracking. Another insulation that can be used is a polymer. Like porcelain, polymers also resist voltage well. However, they are highly susceptible to damage from UV rays.

While both insulation methods have their advantages, porcelain is better because of its durability. It can, therefore, withstand electric pressure and more. Regardless of the material, always ensure they are in good condition. Conduct regular inspections to ascertain they have not degraded.

Regular Maintenance

This is where quality comes into place. Regular maintenance ensures the breaker functions optimally while identifying and rectifying potential hazards. Like the electrical connections, they should be checked regularly. The breaker won't function at all if the connection is loose. Other than that, measure the contact to ensure it’s not worn down. If worn down, replace them because poor contacts are a safety hazard.

Use of High-Quality Materials

Materials like metal allays, vacuum tubes, electronic equipment, etc., are used to manufacture circuit breakers. Each of these components contributes to the overall quality of the circuit. For instance, using high-quality materials to make the VCB contacts will reduce wear and tear.

Conversely, poor-quality materials will deteriorate fast and cause electrical arcing. During arcing, a large amount of energy is released, meaning the circuit is interrupted. While arcing is a necessary evil, too much of it is a potential risk. One way to mitigate it is by ensuring only quality materials are used in the VCB.

Q&A

Q. What is the purpose of a Vacuum Circuit Breaker?

A: To ensure uninterrupted power supply. The breaker also protects electrical system components and improves operational safety. For many years, Siemens has manufactured and improved the vacuum circuit breaker.

Q. What does Water vapor isolation do?

Every time the arc is extinguished, a small amount of gas is released. The gas is water vapor. The vacuum circuit is designed to allow the gas to disperse outside the chamber.

Q. What role do electromagnetic contacts play?

A: Electromagnetic contacts are responsible for closing or opening under the influence of an electric current. The current generates a magnetic field that attracts an armature. This is positioned near the contact. When the current is switched on, the armature is pulled, closing the contact. On the other hand, when the current is off, the armature will release, opening the contact.

Q. What are the colors and meaning of the indicator lights on VCBs?

A: The lights show the present state of the VCB. Hence, they can also be called status indicators. There are several indicator lights, but the most notable are three: red, yellow, and green.

The red light means the circuit breaker is in a trip condition. The yellow light indicates attention is needed; perhaps the internal components are overheating. Last but not least, the green light signifies that the vacuum circuit breaker is functioning properly and is in a stable condition.

Q. What material is used to make the VCB contacts?

A: Because of their exceptional resistance to overheating and wear, silver alloy, copper chrome, and tungsten are the most common materials used in making HVDC circuit breakers and vacuum circuit breakers contacts. These materials can easily handle high temperatures while keeping electrical conductivity at an all-time high. Thanks to their high density, they effortlessly dissipate heat and prevent energy loss.